Ressources

Consultez nos ressources gratuites.

Contactez-nous
Industrial facility with large overhead metal pipes supported by red metal framework under a clear blue sky.

Guides techniques

Tetra a publié une série de guides, disponibles à la commande.

Cover of the HRSG Inspection Planning Guide (2nd Edition)

HRSG Inspection Planning Guide (2nd Edition)

L'inspection fait partie de la maintenance courante de toute chaudière de récupération (HRSG). Des inspections visuelles sont réalisées à intervalles réguliers, conformément aux exigences des organismes de réglementation et des assureurs.

Cover of the HRSG Tube Failure Diagnostic Guide (3rd Edition)

HRSG Tube Failure Diagnostic Guide (3rd Edition)

Les tubes des chaudières de récupération (HRSG) permettent d'extraire l'énergie utile de la chaleur des gaz d'échappement des turbines à gaz dans les centrales à cycle combiné, ou de la chaleur produite par les flux de procédé dans les installations pétrochimiques.

Livres blancs techniques

Une sélection de documents techniques à consulter.

Merci ! Votre demande a bien été reçue.
Oups ! Une erreur s'est produite lors de l'envoi du formulaire.

Classification du fluage de l'acier Grade 91

L'acier Grade 91 surpasse de nombreux autres matériaux industriels par sa résistance accrue à plusieurs modes d'endommagement, dont le fluage.

En savoir plus

Tuyauteries de chaudières de centrale

Les exigences de conception des tuyauteries de chaudière relèvent de deux périmètres, interne et externe.

En savoir plus

Traitement thermique après soudage (PWHT)

Principes du traitement thermique après soudage (PWHT), règles générales de l'ASME Section I (PW-39) et méthode pour déterminer si un PWHT est nécessaire.

En savoir plus

Descriptif de mode opératoire de soudage (DMOS / WPS)

Avant toute opération de soudage, le soudeur et l'ingénieur contrôle qualité doivent connaître parfaitement le contenu du descriptif de mode opératoire de soudage (DMOS).

En savoir plus

Chimie de l'eau dans les HRSG

L'environnement à l'intérieur des tubes de HRSG est un facteur important pour préserver leur intégrité.

En savoir plus

Planification des inspections de HRSG

Élaborer un bon plan d'inspection du HRSG implique plusieurs étapes, de la fixation du calendrier à la revue post-inspection.

En savoir plus
Tetra Engineering logo. Orange triangular pyramid on a black background.Tetra Engineering logo. Orange triangular pyramid on a black background.

Nous contacter

Pour discuter de la manière dont nous pouvons vous aider à améliorer les performances de votre centrale ou à préserver sa valeur dans le temps

Nous contacter

Publications, présentations et articles

Une sélection de publications, présentations et articles issus des grandes conférences et événements du secteur.

Titre
Auteur
HRSG Preservation During Shutdowns: A Key Issue Often Neglected
HRSG Preservation During Shutdowns: A Key Issue Often NeglectedHRSG Preservation During Shutdowns: A Key Issue Often Neglected
Misha Gadher & James Malloy
Modern Power Systems, 2026
What do HRSG tube failure statistics tell us?
What do HRSG tube failure statistics tell us?What do HRSG tube failure statistics tell us?
Misha Gadher & Mark Taylor
Modern Power Systems
Counterfeit, Fraudulent and Suspect Items (CFSI) – Steel and HRSGs
Counterfeit, Fraudulent and Suspect Items (CFSI) – Steel and HRSGsCounterfeit, Fraudulent and Suspect Items (CFSI) – Steel and HRSGs
Taylor M.
IMechE HRSG User Group 2022
Adapting Existing Thermal Desalination Plants to Produce Hydrogen
Adapting Existing Thermal Desalination Plants to Produce HydrogenAdapting Existing Thermal Desalination Plants to Produce Hydrogen
Malloy J.
2022 World Utilities Congress
Root Cause Failure Investigation of MSCV Drain Failures
Root Cause Failure Investigation of MSCV Drain FailuresRoot Cause Failure Investigation of MSCV Drain Failures
P. Jackson, A. Wholey, E. Tsai and D. Burns
ASME 2022 Pressure Vessels & Piping Conference

Projets réalisés

Forte de plus de 35 ans d'expérience dans les services liés à la production d'électricité et de vapeur industrielle, Tetra Engineering a mené de très nombreux projets.

Middle East.

MSV Stellite Cracking Failure Analysis, 2018

Caustic soda is injected into the product water in order to raise the pH as required by the specification. Inspection of GRP piping has often shown large amounts of deposition inside these pipes. Deposition is mostly observed downstream of the injection point of sodium hydroxide and can therefore be attributed to unsuitable chemical injection. Typical injection setups utilise four simple (no nozzle) injection ports aStaff at a CCGT plant engaged Tetra to investigate the root cause of the cracking and damage appearing on the Main Steam Valve (MSV) stellite seat ring(s). The metallurgical analysis identified iron dilution from the F91 valve seat into the hard-facing alloy as the root cause of the debonding.  The extent of the iron dilution is a sign of excessive heat input, most likely caused during the welding process. This points towards the welding during fabrication as the actual root cause of the failure. The driving force for failure / debonding of the Stellite hardfacing could also include residual stresses from welding and/or transient heat transfer stresses and/or thermal shock during operation.t 90° from one another causing ineffective mixing of the flows, leading to the observed precipitation. Tetra performed a CFD analysis of the caustic injection process to investigate the degree of mixing of the two flows and simulate the effects of modifying the volumetric flow rate.

Europe

Root Cause Analysis of HP Drum Nozzle Cracking, 2018

During the 2018 shutdown at a CCGT in Europe several of the HRSG HP drum riser nozzle and downcomer nozzle welds were checked and all were found to be cracked on the inside of the drum, at the weld toe or between weld beads, with the cracks following the fusion line back to the nozzle. The drum feedwater inlet and steam outlet nozzles (above drum waterline) were both undamaged. The drums were removed and all welds were repaired in the workshops. Tetra performed Finite Element Analysis (FEA) and operational data analysis and could conclude that the operational stresses were high enough given the current cycling regime to cause the cracking observed. The quality and design of the original welds is also likely to have contributed to the cracking.

Middle East

Diverter Damper Design & Operation Review, 2018

Tetra was engaged by a client to investigate the recently observed cracking on the diverter damper actuator. The design documentation and failure mode was reviewed. From this initial review it could be concluded that the shaft cracking is most likely a result of the operating procedure, where  the damper is kept in an open position for an extended period of time. The exposure to hot flue gas in combination with the load acting on the toggle arms is the most likely source of the cracking

South East Asia

Flow Accelerated Corrosion Risk Assessment, 2017

An assessment of the susceptibility of HRSG piping components was performed according to Tetra Engineering’s FACRisk™ methodology which includes the use of thermal modelling simulation software (PPSD). From each system, sub groups are ranked using both time to minimum wall thickness and wear rate. The highest risk components (such as elbows, tees and valves) are identified. Overall, due to relatively high operating pH level (>9.2), the overall risk of FAC failures at the CCGT plant in question was considered to be relatively low, with few specific areas showing increased risk. Three separate load cases were simulated and analysed to determine the potential FAC risk. The results of each simulation were incorporated into the final locations recommended for inspection.

Tetra Engineering logo. Orange triangular pyramid on a black background.Tetra Engineering logo. Orange triangular pyramid on a black background.

Nous contacter

Pour discuter de la manière dont nous pouvons vous aider à améliorer les performances de votre centrale ou à préserver sa valeur dans le temps

Nous contacter